The following information is also available:
Here is in index of the event files for each instrument:S0_ARENA= | 0 | / S0 Area discrimination enable/disable |
S0CCDPOW= | 1111 | / Which S0 CCDs are in use(0123): 0=OFF 1=ON |
S0CCDMOD= | 4 | / How many S0 CCDs are in use: 1, 2, or 4 |
S0CCDLST= | 0 1 2 3 | / S0 CCD readout order |
S0_ARENA= | 1 | / S0 Area discrimination enable/disable |
S0CCDPOW= | 1000 | / Which S0 CCDs are in use(0123): 0=OFF 1=ON |
S0CCDMOD= | 1 | / How many S0 CCDs are in use: 1, 2, or 4 |
S0CCDLST= | 0 0 0 0 | / S0 CCD readout order |
S0CCDPOW= | 0001 | / Which S0 CCDs are in use(0123): 0=OFF 1=ON |
S0CCDLST= | 3 3 3 3 | / S0 CCD readout order |
S0CCDPOW= | 1000 | / Which S0 CCDs are in use(0123): 0=OFF 1=ON |
S0CCDLST= | 0 0 0 0 | / S0 CCD readout order |
S1_ARENA= | 1 | / S1 Area discrimination enable/disable |
S1_STAH1= | 257 | / S1 area discrimination H start addr for ccd 1 |
S1_ENDH1= | 405 | / S1 area discrimination H end addr for ccd 1 |
S1CCDPOW= | 1111 | / Which S1 CCDs are in use(0123): 0=OFF 1=ON |
S1CCDMOD= | 4 | / How many S1 CCDs are in use: 1, 2, or 4 |
S1CCDLST= | 0 1 2 3 | / S1 CCD readout order |
S1_STAV1= | 239 | / S1 area discrimination V start addr for ccd 1 |
S1_ENDV1= | 387 | / S1 area discrimination V end addr for ccd 1 |
S1_ARENA= | 1 | / S1 Area discrimination enable/disable |
S1_STAH1= | 276 | / S1 area discrimination H start addr for ccd 1 |
S1_ENDH1= | 387 | / S1 area discrimination H end addr for ccd 1 |
S1CCDPOW= | 0100 | / Which S1 CCDs are in use(0123): 0=OFF 1=ON |
S1CCDMOD= | 1 | / How many S1 CCDs are in use: 1, 2, or 4 |
S1CCDLST= | 1 1 1 1 | / S1 CCD readout order |
S1_STAV1= | 258 | / S1 area discrimination V start addr for ccd 1 |
S1_ENDV1= | 369 | / S1 area discrimination V end addr for ccd 1 |
S1_ARENA= | 0 | / S1 Area discrimination enable/disable |
S1_STAH1= | 276 | / S1 area discrimination H start addr for ccd 1 |
S1_ENDH1= | 387 | / S1 area discrimination H end addr for ccd 1 |
S1CCDPOW= | 1111 | / Which S1 CCDs are in use(0123): 0=OFF 1=ON |
S1CCDMOD= | 4 | / How many S1 CCDs are in use: 1, 2, or 4 |
S1CCDLST= | 0 1 2 3 | / S1 CCD readout order |
S1_STAV1= | 258 | / S1 area discrimination V start addr for ccd 1 |
S1_ENDV1= | 369 | / S1 area discrimination V end addr for ccd 1 |
HVL_LVL= | 4 | / HV-Low level (0 - 7) |
GAIN= | 48 | / Fine Gain level (0 - 63) |
LE_DS= | 0 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | OFF | / RBM auto flag on/off |
POS_DET= | POW2 | / Position determination method (FLF/POW2) |
HVL_LVL= | 4 | / HV-Low level (0 - 7) |
GAIN= | 48 | / Fine Gain level (0 - 63) |
LE_DS= | 0 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | OFF | / RBM auto flag on/off |
POS_DET= | FLF | / Position determination method (FLF/POW2) |
HVL_LVL= | 4 | / HV-Low level (0 - 7) |
GAIN= | 48 | / Fine Gain level (0 - 63) |
LE_DS= | 0 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | ON | / RBM auto flag on/off |
POS_DET= | FLF | / Position determination method (FLF/POW2) |
HVL_LVL= | 3 | / HV-Low level (0 - 7) |
GAIN= | 63 | / Fine Gain level (0 - 63) |
LE_DS= | 3 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | ON | / RBM auto flag on/off |
POS_DET= | FLF | / Position determination method (FLF/POW2) |
HVL_LVL= | 4 | / HV-Low level (0 - 7) |
GAIN= | 40 | / Fine Gain level (0 - 63) |
LE_DS= | 0 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | OFF | / RBM auto flag on/off |
POS_DET= | POW2 | / Position determination method (FLF/POW2) |
HVL_LVL= | 4 | / HV-Low level (0 - 7) |
GAIN= | 40 | / Fine Gain level (0 - 63) |
LE_DS= | 0 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | OFF | / RBM auto flag on/off |
POS_DET= | FLF | / Position determination method (FLF/POW2) |
HVL_LVL= | 4 | / HV-Low level (0 - 7) |
GAIN= | 40 | / Fine Gain level (0 - 63) |
LE_DS= | 0 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | ON | / RBM auto flag on/off |
POS_DET= | FLF | / Position determination method (FLF/POW2) |
HVL_LVL= | 3 | / HV-Low level (0 - 7) |
GAIN= | 51 | / Fine Gain level (0 - 63) |
LE_DS= | 3 | / Lower energy discriminator level (0 - 3) |
RBM_AUTO= | ON | / RBM auto flag on/off |
POS_DET= | FLF | / Position determination method (FLF/POW2) |