VS09X1 Results
Submitted checklist.txt and checklist.tex is also available |
[Summary | AIPS | Difmap ] |
Abstract
DQA reports no fringes to UD. Confirmed Hobart T sys is listed as 350, so I assume that FT is 0.38, even tho it is late for this to be so. single baseline |
|
|
in |
in |
out |
out |
|
FITLD | clint = 0.25 digicor = -1 delcorr = -1 |
|
|
|
|
|
INDXR | cparm = 0, 0, 0.25; |
|
|
|
|
|
ANTAB | infile='antab.txt' |
|
|
|
|
Hobart Tsys is very high by ~ 1.9 -- incorrect? |
APCAL |
|
|
|
|
||
CLCAL | refant=1; |
|
|
|
|
Amplitude calibration solutions applied. HO as ref |
FRING | docal -1; dparm 2,0,0,0.5,0;aparm(7)=0.1;solint 5,10,15 |
|
|
|
|
Full range searched |
SNEDT/SNSMO | bparm 0 0 1/6 1/2 0 |
|
|
|
|
|
CLCAL | refant=1; |
|
|
|
|
|
CALIB | refant=1;solint=5;ante 1;baseli 3; |
|
|
|
|
|
CLCAL | refant=1; |
|
|
|
|
|
SPLIT | aparm(1)=2 0; |
|
|
|
|
Av within IF |
FITTP |
|
|
|
|
Data written out for analysis in Difmap |
AIPS Input Files
ANTAB.TXT | Comments Some HO-UD data missing in FLAGV=1 |
AIPS Output Files
Phase selfcal applied? | No |
Global amplitude selfcal (gscal) applied? | No |
Amplitude selfcal on non-global timescales used? | No |
Modelfit made and saved? | Yes |
Image Made and saved? | No |
Comments on Difmap processing
single baseline point source |
Modelfit | ||||
Ampl, Phase vs (u,v) Distance PS (16 kb) JPEG (35 kb) |
Ampl, Phase vs Time PS (33 kb) JPEG 1 |
(u,v) Coverage PS (8 kb) JPEG (23 kb) | Closure Phase vs Time PS (826 bytes) JPEG 1 |
Image with model components PS (26 kb) JPEG (34 kb) |
More details on the Images and Modelfits are found in this page.