VS07p Results
Submitted checklist.txt and checklist.tex is also available
  [Summary | AIPS | Difmap ]
Analyst: Shinjii HORIUCHI
Date Prepared: 12-12-2001
 

Summary
 
Observation code : VS07p    AIPS Version : 12DEC00   
Date of Observation : 2001/45    Difmap Version : 2.3c 
Source Name : J0321+1221    vsop_difmap used : Yes 
Calibration Source(s) : J0204+15         
Ground telescopes : MP, KA, SH  Model Fitted to data : Yes 
Tracking Station(s) : TZ    Image made : Yes 
Correlator : Penticton         

 
Abstract
This is one of problematical experiments correlated after March 2001, same as vs01s, vs07p, vs08u, vs09p, which suffer significantly lower amplitude, about factor 10 or so, in AIPS comparing DQA1 plots provided by Penticton. We have not yet solve this problem. These data were first correlated with 32 channels/IF. I requested for vs08u to be re-correlated with 128ch/IF but no change in amplitude was observed either in AIPS or DQA1 from previous amplitudes in each system.

This vs07p was the second Penticton correlation made on 11 September 2001. Note that all Penticton data generated after 28 May 2001 has *NO* need for sqrt(2) modification (Rob Shank, private communication). However the DQA plots was based on the first correlation made on 3 May 2001.

Fringes were detected during most of the run for all baselines.

Applying thses solutions without gain-tsys correction, VPLOT in AIPS with averaging all channels provided the amplitude 1.2*10^(-4) for KA-MP baselines, while DQA1 amplitude was 1.4*10^(-3). Assuming (DQA amplitude)*sqrt(2) provided right amplitude, I multiply sqrt(14*sqrt(2)/1.2) = 4.06192E+00 for each antenna in AIPS by CLCOR prior to ANTAB, APCAL etc. to adjust amplitude to that of DQA1.

Tsys information obtained during the experiment was only available for SH. Nominal information was applied for Halca, KA and MP.

The amplitude for target is about 1.0 Jy at 20 Mlambda and 0.3 Jy at 110 Jy while PLS showed 1.2 Jy at 5 Mlambda and 1.0 Jy at 120 Mlambda. For the calibrator about 1.0 Jy at both 20 Mlambda and 120 Mlambda while PLS showed 3.1Jy@5Mlambda and 2.5Jy@120Mlamdga.

There still remains a feeling that the data processed in this manner is about factor 2 or so lower than expected value, but this may be due to variability of the target.

The image is well modelfitted with one gaussian component.

Model
Flux (Jy)
Radius (mas)
Theta (deg)
Major (mas)
Axial ratio
Phi (deg)
TB (10^12 K)
0.679107 0.0846640 -66.4903 0.972182 0.398900 -47.5148 0.0879
(*) Quoted Brightness temperatures assume Gaussian components and are in the local (z=0) frame.



AIPS Data Reduction Notes
 
Task
Adverbs
CL
in
SN
in
CL
out
SN
out
Comments
FITLD
 
 
 
 
 
INDXR
 
 
 
 
 
FRING Solint=10, APARM(7)=2, DPARM=1,400,100,
   0, REFANT=5 (MP)
 
 
 
 
CLCAL
 
SMOTY 'VLBI" 
TACOP
 
 
 
CLCOR OPCODE = 'GAIN',CLPARM =
    4.06192E+00, 0 / Gain
   curve
 
 
To adjust AIPS amplitudes to DQA1 ones (see abstract) 
ANTAB
 
 
 
 
TY1, GC1 are generated. 
APCAL
 
 
 
-------------------------------------------------------- 
CLCAL
 
SMOTY 'AMPL" 
SPLIT
 
 
 
 
FITTP
 
 
 
 
 

AIPS Input Files
Comments
- None -

Additional Files
NameDescription
VS07P.ANTABTsys information obtained during the experiment was only available for SH. Nominal information was applied for Halca, KA and MP.
VS07P.INDXRProvided by PI-letter from Penticton

AIPS Output Files
PRTAN.LIS
LISTR.LIS
DTSUM_0.LIS
DTSUM_1.LIS
UVPLT_UV.PS
UVPLT_UVD.PS
UVPLT_UVPA.PS
SN_APCAL_AMP_2.PS
SN_APCAL_AMP_1.PS
SN_CALIB_DEL_1.PS
SN_CALIB_DEL_2.PS
SN_CALIB_RAT_1.PS
SN_CALIB_RAT_2.PS
SN_CALIB_SNR_1.PS
SN_CALIB_SNR_2.PS
SN_CALIB_PHA_1.PS
SN_CALIB_PHA_2.PS
POSSM_AP1_01.PS
POSSM_AP1_02.PS



Difmap Data Reduction Notes
Phase selfcal applied? Yes
Global amplitude selfcal (gscal) applied? No
Amplitude selfcal on non-global timescales used? No
Modelfit made and saved? Yes
Image Made and saved? Yes
Comments on Difmap processing
The data was fitted with one faussian model.

Image
Ampl, Phase vs (u,v) Distance
PS (52 kb)
JPEG (45 kb)
Ampl, Phase vs Time
PS (162 kb)
JPEG 1, 2
(u,v) Coverage
PS (28 kb)
JPEG (28 kb)
Closure Phase vs Time
PS (125 kb)
JPEG 1
Clean Image
PS (34 kb)
JPEG (51 kb)
Modelfit
Ampl, Phase vs (u,v) Distance
PS (52 kb)
JPEG (45 kb)
Ampl, Phase vs Time
PS (162 kb)
JPEG 1, 2
(u,v) Coverage
PS (28 kb)
JPEG (28 kb)
Closure Phase vs Time
PS (125 kb)
JPEG 1
Image with model components
PS (35 kb)
JPEG (40 kb)

More details on the Images and Modelfits are found in this page.

Model
Flux (Jy)
Radius (mas)
Theta (deg)
Major (mas)
Axial ratio
Phi (deg)
TB (10^12 K)
0.679107 0.0846640 -66.4903 0.972182 0.398900 -47.5148 0.0879
(*) Quoted Brightness temperatures assume Gaussian components and are in the local (z=0) frame.



Last updated on Thu Dec 13 20:32:28 GMT 2001
by db_results.pl version 0.3.